TANDBERG MPS API
User Guide
31
Example 2.21
Exposure options are also supported together with feedback.
User only wants to monitor call setup progression.
xfeedback register status/call--
OK
xcom dial 10.47.15.127
*s Call 1 (status=EstablOut, type=Vtlph, protocol=H323,
direction=Outgoing):
*s/end
*r Result (status=OK):
CallRef: 1
LogTag: 3
*r/end
OK
*s Call 1 (status=Alerting, type=Vtlph, protocol=H323,
direction=Outgoing):
*s/end
CONNECT
*s Call 1 (status=Syncing, type=Vtlph, protocol=H323,
direction=Outgoing):
*s/end
*s Call 1 (status=Synced, type=Vtlph, protocol=H323,
direction=Outgoing):
*s/end
Example 2.22
User only wants to know when calls are connected and disconnected:
xfeedback register status/call[@status="Synced"]--
OK
xfeedback register status/call[@status="Disconnected"]--
OK
xcom dial 10.47.15.127
*r Result (status=OK):
CallRef: 1
LogTag: 4
*r/end
OK
CONNECT
*s Call 1 (status=Synced, type=Vtlph, protocol=H323,
direction=Outgoing):
Przeglądanie stron 32